SCQ25T Quadra Shunt with Tank Level Inputs
4x Current 25A 3x Voltage, 4x Resistive (Tanks/Temp)
SCQ25T is an innovative combination of the SCQ25 shunt module PLUS the T107 Voltage and Resistance input Module with:
- Four current inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak) per input
- Can handle 12V or 24V systems, (same voltage used per device)
- Innovative protected architecture allows wiring in either negative (low) or positive (high) side. (same system used per device)
- Very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power.
- Current channels can be combined for higher amperage, meaning 2 x 25A channels can be used for measuring up to 50A.
- Up to five modules can be connected simultaneously to monitor up to 20 current channels with PICO Battery Monitor.
- Assignable NO or NC output relay.
Plus it is equipped with:
- four resistance inputs for resistance-type tank level or temperature sensors and
- three voltage inputs for voltage-type tanks sensors and battery voltages allows wide connection possibilities.
- assignable relay output NO or NC.
It receives its power to operate via the twisted pair communication cable from the splitter power block.
It is a versatile module for monitoring:
- Tanks of all descriptions
- Temperature sensors
- Battery voltage
- Inclinometer inputs (x and Y need an input each)
- AC current sense
- Irradiation sensor for solar performance
(S004)
Technical specifications
Operating | |
Voltage range | 6 – 35 V |
Temperature range | -20 – +70 °C |
Power consumption at 12V | |
Operating | 3,5 mA |
Current measuring channels | 4 |
Current measuring range | |
Per channel | 0,01 – 50 A |
Accuracy | ± 0,6 % |
Resolution | 0,01 A |
Sampling rate | 100 ms |
Maximal current | |
Continuous | 25 A |
Peak current (<1 min) | 35 A |
Peak current (<5 sec) | 50 A |
Voltage drop at 25 A | 35 mV |
Maximal voltage on connections | 35 V |
Voltage inputs | |
Range | 0 – 35 V |
Resolution | 1 mV |
Accuracy | ± 0,2 % |
Sampling rate | 100 ms |
Resistance inputs | |
Range | 0 ohm – 65 kohm |
Accuracy | ± 3,0% |
Number of connections | Total number of 7 voltage and resistance inputs + 4 x 25A current inputs |
Tank level sensors | 7 (both Voltage and Resistance). If resistance used for temperature then only 3 Tank Sensors |
Temperature sensors | 4 (resistance only) |
SKU | S004 |
Brand | Simarine |
Shipping Weight | 0.5500kg |
Shipping Width | 0.190m |
Shipping Height | 0.070m |
Shipping Length | 0.240m |
Shipping Cubic | 0.003192000m3 |
Unit Of Measure | each |