SCQ25T is a highly verstaile and innovative combination current measurement, tank interface and voltage module. Its highly innovative shunt module with four inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak).
Notify me when back in stock
SCQ25T is an innovative combination of the SCQ25 shunt module PLUS the T107 Voltage and Resistance input Module with:
- Four current inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak) per input
- Can handle 12V or 24V systems, (same voltage used per device)
- Innovative protected architecture allows wiring in either negative (low) or positive (high) side. (same system used per device)
- Very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power.
- Current channels can be combined for higher amperage, meaning 2 x 25A channels can be used for measuring up to 50A.
- Up to five modules can be connected simultaneously to monitor up to 20 current channels with PICO Battery Monitor.
- Assignable NO or NC output relay.
Plus it is equipped with:
- four resistance inputs for resistance-type tank level or temperature sensors and
- three voltage inputs for voltage-type tanks sensors and battery voltages allows wide connection possibilities.
- assignable relay output NO or NC.
It receives its power to operate via the twisted pair communication cable from the splitter power block.
It is a versatile module for monitoring:
- Tanks of all descriptions
- Temperature sensors
- Battery voltage
- Inclinometer inputs (x and Y need an input each)
- AC current sense
- Irradiation sensor for solar performance
(S004)
Technical specifications
Operating | |
Voltage range | 6 – 35 V |
Temperature range | -20 – +70 °C |
Power consumption at 12V | |
Operating | 3,5 mA |
Current measuring channels | 4 |
Current measuring range | |
Per channel | 0,01 – 50 A |
Accuracy | ± 0,6 % |
Resolution | 0,01 A |
Sampling rate | 100 ms |
Maximal current | |
Continuous | 25 A |
Peak current (<1 min) | 35 A |
Peak current (<5 sec) | 50 A |
Voltage drop at 25 A | 35 mV |
Maximal voltage on connections | 35 V |
Voltage inputs | |
Range | 0 – 35 V |
Resolution | 1 mV |
Accuracy | ± 0,2 % |
Sampling rate | 100 ms |
Resistance inputs | |
Range | 0 ohm – 65 kohm |
Accuracy | ± 3,0% |
Number of connections | Total number of 7 voltage and resistance inputs + 4 x 25A current inputs |
Tank level sensors | 7 (both Voltage and Resistance). If resistance used for temperature then only 3 Tank Sensors |
Temperature sensors | 4 (resistance only) |
SKU | S004 |
Brand | Simarine |
Shipping Weight | 0.5500kg |
Shipping Width | 0.190m |
Shipping Height | 0.050m |
Shipping Length | 0.240m |
Shipping Cubic | 0.002280000m3 |
Unit Of Measure | each |