This package designed for 20kW AC EV Charging:

Existing solar system required. installation is additional.

"Travel and Live in a World,
without Consuming the Earth"

Most people with existing solar are selling their excess solar power for a pittance. Electric utilities plan to pay ZERO in the future. If you have an EV now, or plan to have one, Safiery have a solution for you:

1) Install an upgraded hybrid Inverter/Charger to your existing solar.

2) Install a Safiery Lithium system, CEC Accredited with 10 yr warranty.

3) Safiery configure the system for 3 Phase, EVEN IF YOU ONLY HAVE SINGLE PHASE COMING INTO THE HOUSE.

4) Safiery install a Victron 3 Phase EV charging station.

The system will charge the lithium battery bank by day and use excesss solar to charge the EV either before the battery is fully charged or after it is charged. Your choice of strategy. 

Plug in your EV into the Type 2 Socket and let the system do the rest. It will charge at 20kW AC 3 phase.

For EV's with 60kWh lithium, time to charge 10% to 80% is 2.25 hours.

To exclusively use solar, a maximum of 30kWh can be charged per day (weather permitting to recharge battery from solar). As a guide a Tesla model 3 has a consumption rate of 14.9kWh for 200km. So you would add 200km range per day from solar. On the weekend, charging during solar hours should give maximum range for the week ahead.

 

 

Specification:

AN EXISTING SOLAR SYSTEM OF 12-16KWP IS DESIREABLE.

Typical 4 Bedroom Home Profile with Swimming pool & Electric Hot Water
Solar Input Max Energy/ Day Summer House Consumption During Day EV Charging per day for 400km/week Balance for Battery Storage Used at peak time at night
13.3kWp 65kWh 40kWh 12kWh 13kWh 13kWh

 

Technical Data

GW10KL-ET

Battery Type

Li-Ion

Nominal Battery Voltage (V)

500

Battery Voltage Range (V)

180~600

Max. Continuous Charging Current (A)

25

Max. Continuous Discharging Current (A)

25

Max. Charge Power (W)

10,000

Max. Discharge Power (W)

10,000

Max. Solar Input Power (W)

13,300

Max. Solar Input Voltage (V)*1

1000

Solar MPPT Operating Voltage Range (V)*2

200~850

Solar MPPT Voltage Range at Nominal Power (V)*3

320~850

Start-up Solar Panel Voltage (V)

180

Nominal Solar Input Panel Voltage (V)

620

Max. Input Current per MPPT (A)

12.5/22

Max. Short Circuit Current per MPPT (A)

15.2/27.6

Max. Backfeed Current to The Array (A)

0

Number of MPP Trackers

2

Number of Strings per MPPT

1/2

Nominal Apparent Power Output to Utility Grid (VA)

10,000

Max. Apparent Power Output to Utility Grid (VA)*2*4

11,000

Nominal Apparent Power from Utility Grid (VA)

15,000

Max. Apparent Power from Utility Grid (VA)

15,000

Nominal Output Voltage (V)

400/380,

3L/N/PE

Output Voltage Range (V)

0~300

Nominal AC Grid Frequency (Hz)

50/60

AC Grid Frequency Range (Hz)

45~65

Max. AC Current Output to Utility Grid (A)

16.5

Max. AC Current From Utility Grid (A)

22.7

Max. Output Fault Current (Peak and Duration) (A)"

45@2μs

Inrush Current (Peak and Duration) (A)

45@2μs

Nominal Output Current (A)

14.5

Power Factor

 

Max. Total Harmonic Distortion

<3%

Maximum Output Overcurrent Protection (A)

45

Back-up Nominal Apparent Power (VA)

10,000

Max. Output Apparent Power (VA)*3

10,000 (16,500@60

sec)

Nominal Output Current (A)

14.5

Max. Output Current (A)

16.5

Max. Output Fault Current (Peak and Duration) (A)

45@2μs

Inrush Current (Peak and Duration) (A)

45@2μs

Maximum Output Overcurrent Protection (A)

45

Nominal Output Voltage (V)

400/380

Nominal Output Frequency (Hz)

50/60

Output THDv (@Linear Load)

<3%

Max. Efficiency

97.60%

European Efficiency

96.80%

Max. Battery to AC Efficiency

97.50%

MPPT Efficiency

99.90%

PV Insulation Resistance Detection

Integrated

Residual Current Monitoring

Integrated

PV Reverse Polarity Protection

Integrated

Anti-islanding Protection

Integrated

AC Overcurrent Protection

Integrated

AC Short Circuit Protection

Integrated

AC Overvoltage Protection

Integrated

DC Switch

Optional

DC Surge Protection

Type III

AC Surge Protection

Type III

Remote Shutdown

Integrated

Operating Temperature Range (℃)

-35~+60

Relative Humidity

0~95%

Max. Operating Altitude (m)

4000

Cooling Method

 

User Interface

LED, APP

Communication with BMS*6

RS485, CAN

Communication with Meter

RS485

Communication with Portal

 

Weight (kg)

25

Dimension (W×H×D mm)

 

Noise Emission (dB)

<30

Topology

Non- isolated

Self-consumption at Night (W) - no backup power

<15

Ingress Protection Rating

IP66

DC Connector

 

 

(EVC2035601)

SKU EVC2035601