This 7kW Liquid Cooled AC/DC bi-directional converter that converts AC voltage to an adjustable nominal 800v or 400v DC.

Optimized to charge eMobility Li-ION batteries. Protection degree  IP6K9K rated.

Features include:

      Ideal for Emobility applications.

      Universal AC Input (90-264vAC)

      800v or 400v Output versions

      Bi-Directional operation

      High efficiency up to 96%

      3000VAC I/O Isolation

      Liquid Cooled

      Compact Size

      Overload Protection

      Over-temperature Protection

      Under/Over Voltage Shutdown

      CAN Bus Controlled

      Adjustable O/P Voltage

      -40 to 85°C Operating temperature

      Parallel x 3 max.

      Safety approvals, RoHS compliant

      E mark compliant 

 

Dimensions

PARAMETER

DESCRIPTION

UNIT

Dimensions (HxWxD)

475x390x90

mm

Weight

11kg

kg

Enclosure

IP6k9k

 

Input Specifications

PARAMETER

DESCRIPTION

MIN

NOM

MAX

UNIT

Input Voltage

Operating Input Voltage Range (1)

90

230

264

VAC

Input Voltage full power

I/P Voltage range 7kW o/p

220

230

264

VAC

Input Frequency

 

47

 

63

Hz

Input Voltage Shutdown

Converter Shut Down

 

 

 

VAC

Input Current

230v AC I/P Voltage

 

 

32

A

Efficiency

Vin = 230v, Vo = 800v, I nom = A

 

95

 

%

 

 

 

 

 

 

Inrush Current

230vAC i/p

 

20

 

ADC

 

 

 

 

 

 

 

Output Specification 400V DC

PARAMETER

DESCRIPTION

MIN

NOM

MAX

UNIT

Output Voltage Trim Range

Adjustment Of O/P V

220

 

450

VDC

Output Current

Liquid Cooled

 

20

 

ADC

Output Power

Liquid Cooled

 

7000

 

W

Line Regulation

Vin min – Vin max @20A, T Coolant 70c

-0.1

 

+0.1

VDC

Thermal Drift

 

-0.05

 

+0.05

%

Ripple and Noise

@350v O/P 50% load

-3

 

+3

%

Transient Response

10% - 100% O/P load

-1

 

+1

V

Turn On Overshoot

Vo nom

5

 

10

%

Remote Sense

 

 

500

 

mV

Turn on Delay

Rise Time

 

 

200

mS

 

Power On Delay

 

 

1

Sec

 

By PS_ON Signal

 

 

1

Sec

Parallel Operation

Max 3 units in Parallel

 

 

21

kW

Output Over Current

Constant Current

 

 

21

ADC

Output Over Voltage

Latch

460

 

470

VDC

 

Output Specification 800V DC

PARAMETER

DESCRIPTION

MIN

NOM

MAX

UNIT

Output Voltage Trim Range

Adjustment Of O/P V

500

 

900

VDC

Output Current

Liquid Cooled

 

10

 

ADC

Output Power

Liquid Cooled

 

4000

 

W

Line Regulation

Vin min – Vin max @10A, T Coolant 70c

-0.1

 

+0.1

VDC

Thermal Drift

 

-0.05

 

+0.05

%

Ripple and Noise

@700v O/P 50% load

-3

 

+3

%

Transient Response

10% - 100% O/P load

-1

 

+1

V

Turn On Overshoot

Vo nom

5

 

10

%

Remote Sense

 

 

 

 

 

Turn on Delay

Rise Time

 

 

200

mS

 

Power On Delay

 

 

1

Sec

 

By PS_ON Signal

 

 

1

Sec

Parallel Operation

Max 3 units in Parallel

 

 

21

kW

Output Over Current

Constant Current

 

 

11

ADC

Output Over Voltage

Latch

910

 

920

VDC

 

 

 

 

 

 

 

CANbus Control and Monitoring

PARAMETER

DESCRIPTION

MIN

NOM

MAX

UNIT

CAN BUS 2.0 SAE J1939

500kBits/s

 

 

 

 

Address Bits

Internally Pulled to LOGIC HIGH

 

 

 

 

PS_WAKE UP

Logic Input Signal

 

12

 

VDC

HVIL Function

HVIL Pins Internally Shorted

 

 

 

 

+12v

Auxiliary Supply

 

12

 

 

0v

0v

 

 

 

 

 

Safety and Regulatory to Automotive Standards

PARAMETER

DESCRIPTION

 

 

 

 

Insulation

Basic 3000 RMS Input – Earth

Basic 3000 RMS Input - Output

 

Radiation Emissions

ECE R10 ESA Level

 

ESD

IEC 61000-4-2

Performance Criteria B

Radiated EMF

IEC 61000-4-3 (10v/m)

Performance Criteria B

Electrical Fast Transient Burst

IEC 61000-4-4 ISO7637-2

 

RF Conducted Immunity

10v, 0.15 – 80MHZ

Performance Criteria A

RF Disturbances Immunity

SAEJ1113-41

Class A

 

Environmental

PARAMETER

DESCRIPTION

 

 

 

 

Insulation

Basic 3000 RMS Input – Earth Basic 3000 RMS Input - Output

 

Radiation Emissions

ECE R10 ESA Level

 

ESD

IEC 61000-4-2

Performance Criteria B

Radiated EMF

IEC 61000-4-3 (10v/m)

Performance Criteria B

Electrical Fast Transient Burst

IEC 61000-4-4 ISO7637-2

 

RF Conducted Immunity

10v, 0.15 – 80MHZ

Performance Criteria A

RF Disturbances Immunity

SAEJ1113-41

Class A

 

Colling Requirements

RAMETER

DE

 

PARAMETER

DESCRIPTION

UNIT

Max Inlet Cooling Temp

+70c

c

Coolant Mixture

50/50 Propylene, Ethylene Glycol/Water

 

Min Coolant Flow

0.02 l/sec

 

Max Coolant Pressure

20

PSI

Max Pressure Drop

1

PSI

(BID70004001)

SKU BID70004001

Others Also Bought

More From This Category